ESS (M) Sdn Bhd added new photo in Motortronics - Medium Voltage Soft Starters
May 7, 2018 at 06:28 pm —
MVC4 Series

MVC4 Series

The MVC4 Medium Voltage Series Soft Starter is designed to start AC motors in any fixed speed application. It provides maximum protection with "True Thermal Modeling," while allowing smooth, stepless control of acceleration and deceleration. The MVC4 Series guarantees power control and protection for your most important assets. AC Supply Voltage 2300, 3300, 4160, 6000/7200V, 11-15kV VAC +10% to -15%, 50/60 Hz line voltages HP Ratings Up to 10,000HP @ 7.2kV (800 Amps max) Up to 20,000HP @ 15kV (800 Amps max)) SCR Overload Ratings 500% - 60 seconds, 600% - 30 seconds Contact factory for higher rating requirements Overview Soft start & protect any AC motor Motor and starter protection is taken to a new level by combining a high-end motor protection relay with a heavy duty solid state starter. Flexible control features and selectable ramping profiles to match any application... no need to compromise performance. High level circuit isolation via fiber optics (standard on all units) for safety and power quality immunity. Sealed NEMA 12 enclosures are standard equipment, not an expensive option. Soft start & protect any AC motor. The MVC Plus Series starter is designed to start AC motors in any fixed speed application. It provides maximum protection with "True Thermal Modeling," while allowing smooth, stepless control of acceleration and deceleration. The MVC Plus Series guarantees power control and protection for your most important assets. Heavy-duty attitude highest rated power devices for maximum current carrying capacity. Rated at 500% for 60 seconds, the MVC4 Series starter will never be the limiting factor in your application. Powerful sustained gate pulse insures reliable SCR firing without reactors (unlike "wimpy" pulse train designs that require a reactor to prevent SCR and motor damage) . Features Advanced motor protection relay and ramp features programmable via the keypad or a laptop computer. Fiber optically isolated low voltage compartment with up to 110kV BIL rating for safety and reliability. Built-in 120V control power transformer*; voltage and current metering. Load-break / fault-make rated disconnect switch with door safety interlocking.* Visible grounding bar for safe operation. Coordinated motor fuses with blown fuse indicators. Line isolation vacuum contactor.* Fully rated bypass contactor for increased thermal capacity and optional across-the-line starting. Heavy duty SCR stack assemblies with ring transformer isolation for reliable SCR gate firing. RTD Option accepts up to 12 RTD inputs. Zero sequence ground fault protection option. Top entry, bottom exit with room for stress cones. Removable entry plates for easy connections. NEMA 12 gasketed enclosure (NEMA 3R optional). Advanced Protection True Thermal Modeling monitors the motor for excessive thermal conditions due to starting, running and even ambient conditions. Retentive Thermal Memory for continuous overload protection even after a complete power loss. MVC Plus remembers the last thermal condition of the motor, observes the off time via a real-time clock and adjusts the thermal model accordingly. Non-Volatile Memory stores the thermal memory without the need for batteries. True Time Thermal Tracking adjusts the thermal model for different cooling rates based on motor temperature, running state or power loss. Dynamic Reset Response Reset is only allowed after the motor has sufficient thermal capacity for a successful restart. Thermal Model Biasing adjusts for heating effects of phase current imbalance or optional RTD inputs. Flexible Setup Choose the level of overload protection. Programmable Trip Classes selectable from NEMA/UL Classes 5 - 30. Dual Mode Protection separate trip curves for start and run modes (example: Class 20 for start, Class 10 for run). Warning Levels can be programmed and assigned to one of six built-in output relays. Custom Trip Curve programmable based on the motor manufacturer’s data Remote or Automatic Overload Reset can be activated for unattended operations. read more
ESS (M) Sdn Bhd added new photo in Lineator AUHF
May 7, 2018 at 06:24 pm —
Mirus Lineator AUHF 3-Phase Passive Harmonic Mitigation Filters

Mirus Lineator AUHF 3-Phase Passive Harmonic Mitigation Filters

Easily applied to input of a single VSD Input current demand distortion < 8% over entire operating range Capable of reducing VSD / VFD harmonics by up to 10 times Products Details MIRUS Lineator AUHF 3-Phase Passive Harmonic Mitigation Filters An easy to apply, passive filter capable of reducing Variable Speed Drive (VSD) / Variable Frequency Drive (VFD) harmonics by up to 10 times with none of the inherent problems of conventional filters. Features Treats all major harmonics generated by Variable Speed Drives and other 3-phase rectifier loads (5th, 7th, 11th, 13th …) Exceeds 18-pulse performance in a smaller footprint, at lower cost and without sacrificing energy efficiency Easily applied to input of a single VSD No need to phase shift against other VSD’s No need for costly harmonic studies Will meet IEEE 519 standard for both current and voltage distortion Input current demand distortion < 8% over entire operating range Power factor 0.98 lagging to 0.95 leading over the normal operating range Compatible with engine generators since capacitive reactance is < 15% of rated kVA even under light loads Will not resonate with other power system components Will not be overloaded by other line side harmonic sources Suppresses overvoltages caused by capacitor switching and other fast changing loads Eliminates need for drive isolation transformers, AC line reactors and DC link chokes Removal of harmonics improves overall system power factor Saves energy by reducing upstream harmonic losses while operating at > 99% efficiency Reduces DC bus ripple and increases ride-through capability of the load read more
ESS (M) Sdn Bhd added new photo in Danfoss / Vacon
May 7, 2018 at 06:22 pm —
Vacon® 100 Flow

Vacon® 100 Flow

Dedicated functionality for pumps, fans and compressors VACON® 100 FLOW is an AC drive that is dedicated to improving flow control and saving energy in industrial pump and fan applications. Specifically designed features include Multipump solutions and application selection menus. They enhance pump performance and protect pipes and equipment to ensure reliable operation. Standard PID control uses a sensor to control pump speed instead of an external controller. This helps the drive to quickly react to fluctuations in demand for accurate process control and optimized energy savings. Power range and supply voltages 3 x 208-240 V...0.55-90 kW 3 x 380-500 V...1.1-630 kW 3 x 525-690 V...5.5-800 kW Features and benefits Fast and efficient system integration thanks to dedicated functionality for pump, fan and compressor applications Extended drive lifetime and minimized lifecycle costs due to electrolytic-free DC link capacitors Easy commissioning and start-up as a result of graphical keypad and wizard guides Efficient integration into automation systems thanks to built-in Ethernet and RS485 communication Applications Fans, pumps, compressors, chillers and distribution, desalination and water-treatment applications. PC tools VACON Live VACON Loader VACON Customizer NCIPConfig VACON Save Danfoss ecoSmart Danfoss HCS (Harmonic Calculation Software) read more
ESS (M) Sdn Bhd added new photo in Motortronics - Phase Controllers
May 7, 2018 at 06:18 pm —
1P1 - Single Phase SCR Power Control

1P1 - Single Phase SCR Power Control

AC Supply Voltage 120 / 208 / 240 / 380 / 415 / 480 / 575 Vac Current Ratings 20 to 600 Amps Analog Input Signal: 4 to 20ma, 0 to10 Vdc Overview Phasetronics Model 1P1 Series of single-phase SCR Power Controllers feature phase angle control to provide smooth proportional output power from 0 – 100%. The model 1P1 controllers are available with load current ratings ranging from 120 through 575Vac. These units are ideally suited for all resistive, inductive and lamp type loads. With a variety of standard pre-engineered options, they are the ideal choice for system designers, panel builders and end users. Standard features on all Model 1P1 units include isolated heatsink design through 75 amperes, fast blow fuses and transient voltage protection networks, and high PIV rated SCR’s. State-of-the-art digital electronics with hard fi?ring gate pulse and associated logic control circuitry allows these units to accept a variety of input control signals. read more
ESS (M) Sdn Bhd added new photo in Motortronics - Motor Winding Heater Controls
May 7, 2018 at 06:14 pm —
MWH

MWH

Keep motors warm and moisture-free during extended shut-down periods. AC Supply Voltage 200 to 600 Vac\ HP Ratings 3 to 900 HP Easy to Install Whether retrofitting an existing starter or installing a new one, the MWH Series is easy to apply. Just wire it in parallel to the magnetic starter’s line and load connection, connect the necessary auxiliary contacts and installation is complete. Simple Adjustment Output voltage is factory set to maintaina +5° to 10°C differential above ambient temperature. This adjustment can be used to trim the control as required for each application. Self Protected In addition to built-in fuse protection, the MWH Series features an RC snubber circuit across the SCR which protects it from any rapid rate of change in the system voltage. A metal oxide varistor (MOV) protects the unit against voltage spikes for reliable, maintenance-free operation. Fully Automatic Operation Designed for fully automatic operation, the MWH Series turns on when the motor starter has turned off. A built-in one minute timer ensures that the motor magnetic field has collapsed before it injects DC power into the windings. When the motor is restarted, the MWH Series instantly turns off. No operator interface is required... the MWH Series is in control. Built-in Overload Sensing The MWH Series had an optional shutdown input that can be connected to the N.O. auxiliary contact on the motor starter’s thermal overload relay. This will disable the motor winding heater control, preventing any additional heating in the motor and allowing for a faster motor cool down period. The MWH Series then goes back on-line after the overload relay is reset. Ideal Alternative to Strip Heaters Eliminate the cost and hassle of installing strip heaters into your motors. Simply wire up the MWH Series to generate heat throughout the motor stator windings. The heat is dissipated evenly without the “hot spots” caused by strip heaters. Conduction of heat to the rotor, bearings and shaft is also more effective which means maximized protection for the whole motor. read more
ESS (M) Sdn Bhd added new photo in Motortronics - Motor RTD Monitor & Relay Device
May 7, 2018 at 06:10 pm —
TE-RTD12 Motor RTD Monitor & Relay Device

TE-RTD12 Motor RTD Monitor & Relay Device

12 built-in RTD Inputs 2 Isolated Digital Inputs (4-20mA) 3 Programmable Form-C Output Relays 2 Isolated Analog Inputs (4-20mA) Differential Current Feedback Monitoring RS485 MODBUS-RTU Communication Overeview The TE-RTD12 Relay device adds advanced RTD (Resistor Temperature Detector) and differential current monitoring capability to your new or existing motor system. The TE-RTD12 Relay device offers 12 built-in RTD inputs, 3 programmable output relays (5A), 2 isolated analog inputs (4-20mA), 1 isolated analog output (4-20mA), 3 isolated digital inputs, and differential current feedback monitoring. Additionally, an RS485 (2 wire) communication port is available for use with a master device (PLC / SCADA / Operator Interface) for the purpose of programming and/or monitoring. Programmable relay outputs are provided that can be configured for a system function or for use as a global Alarm or Trip based on temperature readout, which can be entered in ºC or ºF. A built-in event recorder stores fault history of past events with data points including Alarm / Trip Code, Current / Temperature value, Analog input value and Date / Time Stamp. The TE-RTD12 Relay device can be mounted on a back panel using the mounting bracket or DIN-Rail mount. RTD Inputs Programmable Alarm Temperature for each RTD in ºC or ºF RTD Type: 100 Ohm Pt, 10 Ohm Cu, 100/120 Ohm Ni Description Selection Digital Inputs (3 Isolated) Programmable Time Delay Normally Open and Normally Closed Selection Digital Outputs (3 Relay Form C) Selectable Function (19) Latched and Unlatched Selection Analog Inputs 4 - 20mA (2 Isolated) User Scaling Selectable Function: User, Oscillation, Airflow, Speed, Pressure Programmable Trip Level Analog Output 4 - 20mA (1 Isolated) User Scaling Selectable Function (6) Differential CT Feedback Monitoring Programmable Differential CT Alarm Level Programmable Differential CT Trip Level Programmable Delay Time Fault History / Event Log Fault History and Event Log (up to 447 Events) Real-time Clock read more
ESS (M) Sdn Bhd added new photo in Motortronics - Electronic Motor Brakes
May 7, 2018 at 06:08 pm —
Stop AC Motor Loads Quickly and Safely... as easy as A-B-C

Stop AC Motor Loads Quickly and Safely... as easy as A-B-C

AC Supply Voltage 200 to 600 Vac HP Ratings 3 to 1000 HP Overview Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The ABC Series "automatic braking controller" features full-wave DC braking which can be adjusted to stop your load quickly, repeatably and reliably...even if load conditions change. The ABC Series meets the three main objectives that are important in every industry: Maximized Safety, Increased Productivity and Maintenance-Free Operation. Maximum Safety Protect Machinery & Operators The ABC Series is designed to eliminate dangerous coast-to-stop times of rotating machines and equipment. The ABC Series also eliminates the dangerous practice of jamming the machine to bring it to a stop, which can present potential danger to operators and passers-by alike. OSHA and other safety agencies pay close attention to these types of operating conditions and recognize brakes as an important part of a system to guard against potential dangers. The ABC Series is an ideal way to add braking and eliminate dangerous "coast-to-stop" times in your application. Increased Productivity Stop AC Motors Quickly for a Profitable Operation Long coast-to-stop times equal lost production time. Now you don't have to wait forever for the load to come to a stop before you make blade changes or change a tool. Simply stop your equipment using an ABC Series electronic brake for increased efficiency and product through-put. The ABC Series also eliminates any need for "plug reversing." Reversing a load when it is still spinning creates mechanical shock which can cause equipment breakage and extended downtime. Your machinery can now do what it was designed to do... make product at a profit. Maintenance Free Operation Eliminate Costly Down Time Using the ABC Series electronic brake eliminates the wear and tear on mechanical brakes in the system. This means less time and money is spent replacing discs or pads (which is especially important given the "shorter life" material used in today's mechanical brakes). Let the mechanical brake act as a holding brake and let the ABC Series do the stopping. The ABC Series eliminates the common (and also dangerous) practice of "jamming" equipment to stop the load. Expensive blades and tooling are no longer "sacrificed" to stop your motor. The ABC Series for faster, smoother stopping and maintenance free operation. Easy to Install The ABC Series microprocessor insures proper connections and coordinates system operation. Simply wire the ABC Series electronic brake into the motor starter circuit for a cost effective, maintenance-free means of bringing the motor and load to a stop. No isolation contactors, no additional logic wiring...it works right off the motor input leads! It's as easy as A-B-C. Easy to Select The ABC Series units are sized by amperage and should be selected based on the application requirements. "Standard Duty" ratings are sized for 95 - 110% of motor FLA. "Extra Duty" ratings are sized for 150 - 250% of motor FLA. Specify maximum braking current and voltage when ordering. read more
ESS (M) Sdn Bhd added new photo in Motortronics - Low Voltage Soft Starters
May 7, 2018 at 06:00 pm —
VMX Series Compact Soft Starter

VMX Series Compact Soft Starter

AC Supply Voltage: 200 - 600 Vac HP Ratings: 3 to 1200 HP Amp Ratings: 18 to 1250 Amps Overload: 500% for 60 sec. Enclosure: Available as Module Only or in NEMA 1/12 Overview Flexibility of Control Multiple ramp profiles, Pump-FlexTM Decel and advanced motor protection make the VMX Series soft starter adaptable to a wide variety of AC motor applications... no need for add-on modules or costly auxiliary devices. Compact packaging has become critical in more and more electrical installations. The VMX Series meets this need without compromising features and ratings. By using a highly engineered packaging design and the latest generation microprocessor, all the control and protection features you need are in the VMX Series. Narrow and shallow dimensions are perfect for integrating the VMX Series into motor control centers (MCCs), pump control panels, and retrofit starter enclosures. Integral Bypass Contactors are standard on all sizes and provide maximum efficiency of panel space while maintaining the Motortronics reputation for being able to soft start m read more
next page